Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Clin Imaging ; 52: 193-199, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30103108

RESUMO

INTRODUCTION: Chemotherapy prolongs the survival of patients with advanced and metastatic tumors. Since the liver plays an active role in the metabolism of chemotherapy agents, hepatic injury is a common adverse effect. The purpose of this study is to compare a novel quantitative chemical shift encoded magnetic resonance imaging (CSE-MRI) method with conventional T1-weighted In and Out of phase (T1 IOP) MR for evaluating the reproducibility of the methods in an oncologic population exposed to chemotherapy. MATERIALS AND METHODS: This retrospective study was approved by the institutional review board with a waiver for informed consent. The study included patients who underwent chemotherapy, no suspected liver iron overload, and underwent upper abdomen MRI. Two radiologists independently draw circular ROIsin the liver parenchyma. The fat fraction was calculated from IOP imaging and measured from IDEAL-IQ fat fraction maps. Two different equations were used to estimate fat with IOP sequences. Intra-class correlation coefficient and repeatability coefficient were estimated to evaluate agreement between two readers on iron level and fat fraction measurement. RESULTS: CSE-MRI showed a higher reliability in fat quantification compared with both IOP methods, with a substantially higher inter-reader agreement (0.961 vs 0.372). This has important clinical implications. CONCLUSION: The novel CSE-MRI method described here provides increased reproducibility and confidence in diagnosing hepatic steatosis in a oncologic clinical setting. IDEAL-IQ has been proved to be more reproducible than conventional IOP imaging.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Fígado/diagnóstico por imagem , Neoplasias/complicações , Idoso , Fígado Gorduroso/complicações , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
Eur J Radiol ; 102: 102-108, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29685522

RESUMO

PURPOSE: Clinical applications of dual energy computed tomography (DECT) have been widely reported; however, the importance of the different image reconstructions and radiation organ dose remains a relevant area of investigation, particularly considering the different commercially available DECT equipment. Therefore, the purpose of this study was to assess the image reliability and compare the information content between several image reconstructions in a rapid-switching DECT (rsDECT), and assess radiation organ dose between rsDECT and conventional single-energy computed tomography (SECT) exams. MATERIALS AND METHODS: This Institutional Review Board-approved retrospective study included 98 consecutive patients who had a history of liver cancer and underwent multiphasic liver CT exams with rsDECT applied during the late arterial phase between June 2015 and December 2015. Virtual monochromatic 70 keV, material density images (MDI) iodine (-water) and virtual unenhanced (VUE) images were generated. Radiation dose analysis was performed in a subset of 44 patients who had also undergone a multiphasic SECT examination within 6 months of the rsDECT. Four board-certified abdominal radiologists reviewed 24-25 patients each, and a fifth radiologist re-evaluated all the scans to reach a consensus. The following imaging aspects were assessed by the radiologists: (a) attenuation measurements were made in the liver and spleen in VUE and true unenhanced (TUE) images; (b) subjective evaluation for lesion detection and conspicuity on MDI iodine (-water)/VUE images compared with the virtual monochromatic images/TUE images; and (c) overall image quality using a five-point Likert scale. The radiation dose analyses were evaluated in the subset of 44 patients regarding the following parameters: CTDIvol, dose length product, patient's effective diameter and organ dose using a Monte Carlo-based software, VirtualDose™ (Virtual Phantoms, Inc.) to 21 organs. RESULTS: On average, image noise on the TUE images was 49% higher within the liver (p < 0.0001) and 48% higher within the spleen (p < 0.0001). CT numbers for the spleen were significantly higher on VUE images (p < 0.0001). Twenty-eight lesions in 24/98 (24.5%) patients were not observed on the VUE images. The conspicuity of vascular anatomy was considered better on MDI iodine (-water) Images 26.5% of patients. Using the Likert scale, the rsDECT image quality was considered to be satisfactory. Considering the subset of 44 patients with recent SECT, the organ dose was, on average, 37.4% less with rsDECT. As the patient's effective diameter decreased, the differences in dose between the rsDECT and SECT increased, with the total average organ dose being less by 65.1% when rsDECT was used. CONCLUSION: VUE images in the population had lower image noise than TUE images; however, a few small and hyperdense findings were not characterized on VUE images. Delineation of vascular anatomy was considered better in around a quarter of patients on MDI iodine (-water) images. Finally, radiation dose, particularly organ dose, was found to be lower with rsDECT, especially in smaller patients.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Iodo , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
3.
J Comput Assist Tomogr ; 42(2): 222-229, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29489589

RESUMO

OBJECTIVE: To evaluate the accuracy of single-source dual-energy computed tomography (ssDECT) in iodine quantification using various segmentation methods in an ex vivo model. METHODS: Ten sausages, injected with variable quantities of iodinated contrast, were inserted into 2 livers and scanned with ssDECT. Material density iodine images were reconstructed. Three radiologists segmented each sausage. Iodine concentration, volume, and absolute quantity were measured. Agreement between the measured and injected iodine was assessed with the concordance correlation coefficient (CCC). Intrareader agreement was assessed using the intraclass correlation coefficient (ICC). RESULTS: Air bubbles were observed in sausage (IX). Sausage (X) was within the same view as hyper-attenuating markers used for localization. With IX and X excluded, CCC and ICC were greater than 0.98 and greater than 0.88. When included, CCC and ICC were greater than 0.94 and greater than 0.79. CONCLUSIONS: Iodine quantification was reproducible and precise. However, accuracy reduced in sausages consisting of air filled cavities and within the same view as hyperattenuating markers.


Assuntos
Iodo/análise , Fígado/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Animais , Bovinos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes
5.
Chin Clin Oncol ; 6(6): 62, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29307202

RESUMO

Pancreatic ductal adenocarcinoma (PDAC) is one of the deadliest cancers worldwide due to its aggressiveness and the challenge to early diagnosis. Complete surgical resection is the only curative option, but fewer than 20% of patients have potentially resectable disease at the time of the diagnosis. Radiologists can assess whether PDAC is resectable, borderline resectable, locally advanced or metastatic based on current imaging tests. This review will outline the role of imaging in both the diagnosis and staging of PDAC, with the goal of assisting the multidisciplinary team in tailoring the best treatment for patients.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Carcinoma Ductal Pancreático/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Adenocarcinoma/diagnóstico , Adenocarcinoma/patologia , Carcinoma Ductal Pancreático/diagnóstico , Carcinoma Ductal Pancreático/patologia , Humanos
6.
Can Assoc Radiol J ; 64(3): 182-6, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22884229

RESUMO

PURPOSE: Chondromalacia patellae is a common cause of anterior knee pain in young patients and can be detected noninvasively with magnetic resonance imaging (MRI). The purpose of our study was to evaluate the correlation between subcutaneous fat thickness around the knee joint on axial MRIs as a surrogate marker of obesity, with the presence or absence of chondromalacia patellae. METHODS: A retrospective review was conducted of knee MRIs in 170 patients who satisfied the inclusion criteria. Imaging was performed over a 12-month period on a 1.5T MRI system with a dedicated extremity coil. Two radiologists experienced in musculoskeletal imaging assessed each examination in consensus for the presence or absence of chondromalacia patellae and graded positive studies from 0 (absent) to 3 (full cartilage thickness defect). Measurement of subcutaneous knee fat thickness was obtained on the medial aspect of the knee. RESULTS: MRI findings of chondromalacia patellae were present in 33 patients (19.4%), of which, there were 11 grade 1 lesions (33.3%), 9 grade 2 lesions (27.3%), and 13 grade 3 lesions (39.4%). The mean subcutaneous knee fat thickness was significantly higher in the chondromalacia patellae group for all grades compared with the normal group (P < .001), and there was a significant correlation between subcutaneous knee fat thickness and grades of chondromalacia patellae (R = 0.48 [95% confidence interval, 0.38-0.68]; P < .001). Female patients had thicker subcutaneous knee fat and more severe grades of chondromalacia patellae. CONCLUSION: Subcutaneous knee fat thickness as a surrogate marker of obesity was positively associated with the presence and severity of chondromalacia patellae on MRI.


Assuntos
Pesos e Medidas Corporais/métodos , Condromalacia da Patela/diagnóstico , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/métodos , Gordura Subcutânea/patologia , Adolescente , Adulto , Criança , Condromalacia da Patela/complicações , Condromalacia da Patela/patologia , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/patologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
7.
BMJ Case Rep ; 20102010 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22798298

RESUMO

We report the case of a 70-year-old man who presented with short-term memory impairment and a homonymous left inferior quadrantanopia secondary to simultaneous bilateral posterior cerebral artery (PCA) territory infarction. As in more than a quarter of cases of PCA infarction, no aetiological cause was identified. Unlike the transient nature of symptoms in some cases following unilateral infarction, his deficits persisted on 2-month follow-up.


Assuntos
Hemianopsia/etiologia , Infarto da Artéria Cerebral Posterior/diagnóstico , Transtornos da Memória/etiologia , Memória de Curto Prazo , Idoso , Anticolesterolemiantes/uso terapêutico , Anti-Hipertensivos/uso terapêutico , Aspirina/uso terapêutico , Atorvastatina , Confusão/tratamento farmacológico , Confusão/etiologia , Dominância Cerebral/fisiologia , Quimioterapia Combinada , Fibrinolíticos/uso terapêutico , Ácidos Heptanoicos/uso terapêutico , Humanos , Infarto da Artéria Cerebral Posterior/tratamento farmacológico , Imageamento por Ressonância Magnética , Masculino , Transtornos da Memória/tratamento farmacológico , Perindopril/uso terapêutico , Pirróis/uso terapêutico , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...